用脂肪和肌肉掩码提升人体磁共振图像配准精度,助力大规模健康研究。
A method for tissue-mask supported whole-body image registration in the UK Biobank
- 利用脂肪与肌肉掩码辅助强度匹配的图割配准方法。
- 男性/女性平均骰率0.77/0.74,比纯强度法高6个百分点。
- 配准结果更稳定,适合年龄与组织特征关联分析。
英国生物银行(UK Biobank)是大规模收集影像与非影像健康数据的研究项目。对全身体积磁共振图像进行鲁棒且精确的跨受试者配准,可实现空间标准化,并开展非影像数据与影像衍生参数的体素级相关分析。本文提出一种基于性别的跨受试者全身体积MRI图像配准方法,采用先进分割器VIBESegmentator生成的皮下脂肪与肌肉掩码,增强基于强度的图割配准。在4000名受试者上评估该方法,对比了仅强度方法及uniGradICON、MIRTK两种方法,指标包括雅可比行列式折叠频率、骰率(Dice score)与体素标签误差频率。同时使用MRSegmentator与TotalSegmentator进行独立骰率验证。还研究了年龄与脂肪含量、组织体积间的体素级相关性以展示其医学研究价值。结果表明,该掩码支持方法相比强度法折叠频率更低;男女平均骰率为0.77/0.74,较强度法分别提高6个百分点,多数区域标签误差减少;相较uniGradICON提升9pp/8pp,相较MIRTK提升12pp/13pp。在MRSegmentator与TotalSegmentator上的骰率也更高。年龄相关图更平滑,解剖对齐更好。结论:基于双组织掩码的配准方法显著提升了英国生物银行图像的全身体积配准性能。
原文摘要 · Abstract (English)
The UK Biobank is a large-scale study collecting imaging and non-imaging health data. Robust and accurate inter-subject image registration of these whole-body MR images would enable their spatial standardization, and region/voxel-wise correlation analysis of non-imaging data with image-derived parameters. We propose a sex-stratified inter-subject whole-body MR image registration approach that uses subcutaneous adipose tissue- and muscle-masks from the state-of-the-art VIBESegmentator method to augment intensity-based graph-cut registration. The proposed mask-supported method was evaluated on 4000 subjects by comparisons to an intensity-only method as well as two other methods, uniGradICON and MIRTK. The evaluation included Jacobian Determinant (JD) folding frequency, Dice scores, and voxel-wise label error frequency. MRSegmentator and TotalSegmentator were also used for independent Dice score evaluations. Additionally, voxel-wise correlation between age and both fat content and tissue volume was studied to exemplify the usefulness for medical research. The proposed method showed lower frequency of JD folding when compared to the intensity-based method. The mask-supported method exhibited a mean Dice score of 0.77 / 0.74 when evaluated on the VIBESegmentator masks for males / females, respectively. In comparison to the intensity-only method, the mean values were 6 pp higher for both sexes, and the label error frequency decreased in most regions. These differences were 9pp / 8pp against uniGradICON and 12pp / 13pp against MIRTK. The proposed method showed higher mean Dice scores in comparison to the other methods when evaluated on MRSegmentator and TotalSegmentator. The age-correlation maps were less noisy and showed higher anatomical alignment. In conclusion, the image registration method using two tissue masks improves whole-body registration of UK Biobank images.
Thank you to arXiv for use of its open access interoperability. PaperDance 不是 arXiv 官方产品;中文卡片由大模型生成,请以原文为准。